Ultrasonic Flow meter

An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow or by measuring the frequency shift from the Doppler effect. They do not use moving parts, unlike mechanical flow meters.

Ultrasonic flow meter Overview

Ultrasonic flow meters are highly useful in a variety of applications across multiple industries.
No moving parts in ultrasonic flow meters, Since ultrasonic flow meters don’t involve moving parts, they last a long time with very little maintenance. As long as the meter is properly mounted and installed, these meters are highly accurate.
However, inline and insertion flowmeters are generally more accurate than clamp-on ultrasonic flow meters.

Ultrasonic flow meters Principle

Electromagnetic flow meters detect flow by using Faraday’s Law of induction.
Inside an electromagnetic flow meter, there is an electromagnetic coil that generates a magnetic field, and electrodes that capture electromotive force(voltage). Due to this, although it may appear as if there is nothing inside the flow pipe of an electromagnetic flow meter, flow can be measured.

FEATURES

PRODUCT BENEFITS

Mass & Volumetric flow monitoring of most liquids without bubbles

  • The foremost advantage is fixed parts
  • Not affected by contamination of the liquid
  • Easy to maintain with a low maintenance cost
  • Capable of operating in both directions

Easy to Install, lots of field installation options

Rugged, long-lasting design for the toughest applications

SPECIFICATIONS

Pipe diameter:1/2″inch to 300″inch

Accuracy:1.0%,1.5%

 Repeatability:0.33%,0.5%

Pressure rate:≤6 Bar,≤10 Bar,≤16 Bar,≤25 Bar,≤40 Bar

Temperature:≤80℃(Normal),≤200℃(High temperature)

Velocity:0.1-5m/s

Ambient temperature:
Operating: -20° to 60°C
Storage: -40° to 65°C

ELECTRIC

Power supply:90-250VAC,24VDC 500mA,3.6V Battery

Output signal:

  • 4-20mA
  • Pulse
  • User-definable pulse output for totalized flow

Digital communications: RS485, Hart

Hazardous-Area Location Enclosure

CONNECTION TYPE

Inline type

Module type

Portable type

Handheld type

Wall mounted Type

Documents

Drawings

  • inline Ultrasonic Flow meter 1“ inch drawing
  • inline Ultrasonic Flow meter 1.5“ inch drawing

Program

  • RS485 Protocol
  • Hart Protocol