Open Channel Flow meter

Ultrasonic Open Channel flow meter measure the level, flow rate, and total volume of water flowing through weirs, flumes, channels, and partially filled pipes. These meters perform best where the sediment does not build up.

Open Channel Flow meter Overview

Open Channel flow meters are an economical and reliable solution that can retain a historical log of all measurements.

  • Economical Solution. This single metering solution is simple to set up and can measure level, flow rate, and total volume in your application.
  • Reliable Performance. Designed to measure level, flow rate, and total volume of water utilizing a non-contact ultrasonic level sensor that delivers impressive accuracy.
  • Monitor Data. Ensures all the measurements are available over Modbus RTU or logged in a historical database for convenience.

Open Channel Flow Meter Parameter

TypeParshall FlumeCut-throat FlumeTriangular WeirRectangular Weir
Flow Range0.36-334800m3/h2.52-10800m3/h0.72-6480m3/h5-176400m3/h
Accuracy±2.5%F.S±5.0%F.S±2.5%F.S±4.0%F.S
MaterialStainless Steel/FiberglassStainless Steel
Stainless SteelStainless Steel

FEATURES

Parshall Flume Chart

SNWL1L2L3LH1HB1B2
11″Inch356762036351924816793
22″Inch40611425477422276214135
33″Inch45715230591425482259178
46″Inch610305610152576686400394
59″Inch864305457162676838575381
610″Inch1325600920284580880780550
712″Inch13506009202870801030840600
818″Inch142560092029458010301020750
924″Inch150060092030208010301200900
1030″Inch1575600920309508103013801050
1136″Inch1650600920317008103015601200
1240″Inch1705600920322580108016801300
1348″Inch1800600920332008108019201500
1460″Inch1950600920347080108022801800

Products show

Parshall flume

Remote TYPE

IP68 probe

Felid Indicator

Battery powered

Documents

Drawings

  • inline vortex Flow meter 1“ inch drawing
  • inline vortex Flow meter 1.5“ inch drawing

Program

  • RS485 Protocol
  • Hart Protocol

Related Products

Ultrasonic meter

Turbine Meter

Pressure Transmitter

Flow Totalizer

Orifice Plate